Calculated to control weight

Calculated to control weight

4xWall thicknessx(Side-Wall thickness)x7.85

Among them, the side length and thickness are in millimeters as a unit, directly into the above-mentioned numerical formula is derived for each square meter of the weight, in grams.

30x30x2.5 mm, such as side pipes, according to the above formula to calculate their weight per meter:

4x2.5x(30-2.5)x7.85=275x7.85=2158.75g,about 2.16kg

When the wall thickness and length are in millimeters when, 4x wall thickness x (side length - thickness) is calculated per meter of pipe length to the size of a cubic centimeter as a unit, and then multiplied by the proportion of iron per cubic centimeter 7.85 grams, which is drawn tube per meter square in grams of weight.